Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Oral Investig ; 28(3): 197, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38448748

RESUMO

OBJECTIVES: This study aimed to investigate the strain in the bone surrounding dental implants supporting a 4-unit bridge and assess the role of excessive strain as a possible risk factor for implant related sequestration (IRS) or peri-implant medication-related osteonecrosis of the jaw (PI-MRONJ). MATERIALS AND METHODS: A 3D-mandibular model was constructed using computed tomography and segmented it into cortical and cancellous bones. The 4-unit implant-supported bridges replacing the mandibular posteriors were constructed, and each featuring two, three, and four implants, respectively. The Young's modulus was assigned based on the quality of the bone. A maximum occlusal force of 200 N was applied to each implant in the axial and in a 30-degree oblique direction. RESULTS: The maximum principal strain of the fatigue failure range (> 3000 µÎµ) in the bone was analyzed. The volume fraction of fatigue failure was higher in poor-quality bone compared to normal bone and oblique load than in axial load. An increasing number of implants may dissipate excessive strain in poor-quality bones. CONCLUSIONS: Occlusal force applied to poor-quality bone can result in microdamage. Given that unrepaired microdamage may initiate medication-related osteonecrosis of the jaw, long-term occlusal force on fragile bones might be a risk factor. CLINICAL RELEVANCE: When planning implant treatment for patients with compromised bone status, clinical modifications such as strategic placement of implants and optimization of restoration morphology should be considered to reduce excessive strain which might be associated with IRS or PI-MRONJ.


Assuntos
Implantes Dentários , Osteonecrose , Humanos , Força de Mordida , Módulo de Elasticidade , Mandíbula
2.
Maxillofac Plast Reconstr Surg ; 45(1): 26, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37526800

RESUMO

BACKGROUND: This study aimed to analyze the clinical outcome and complications of narrow-diameter dental implants (NDIs) (diameter ≤3.5 mm). METHODS: The 274 NDIs that met the selection criteria from 2013 to 2018 were included in the retrospective study, and the survival rates (SVR) were compared. Mechanical complications included screw loosening and fractures of the implant components, such as the implant fixture, abutment, and prosthesis. In addition, marginal bone loss (MBL) was measured immediately after surgery and 1 year after loading. RESULTS: The 3-year cumulative SVR was 92.4%. Nineteen fixtures failed during the follow-up. The failure rate was significantly higher (OR=4.573, p<0.05) in smokers and was significantly higher in osteoporosis patients (OR=3.420, p<0.05). The vertical and horizontal values of MBL were 0.33±0.32 mm and 0.18±0.17 mm, respectively. Mechanical complications included screw loosening (5.5%) and porcelain fracture (2.2%), but no fractures of the fixture or components were observed. The choice of titanium and zirconium (TiZr) alloy implant was significantly more frequent in the posterior region. Bone graft was significantly more frequently done in the anterior region. CONCLUSIONS: According to the high SVR and stability of NDIs, the findings of the study suggest that NDIs may be a replacement for regular diameter dental implants (RDIs) and the use of TiZr alloy could extend the indication of NDIs. In the esthetic area, contour augmentation may be a reason for increasing the frequency of bone grafts.

3.
Materials (Basel) ; 16(13)2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37445067

RESUMO

The biomechanical effects of dental tissue according to various dental crown materials were investigated using finite element analysis. Bone, prepared tooth, root canal, and periodontal ligament were modeled based on computed tomography. Depending on the characteristics of the crown material, it was classified into zirconia, hybrid ceramic, gold alloy, and acrylic resin. A loading force of 200 N was applied in the vertical direction to the occlusal surface of the crown, and analysis was performed under the condition that all interfaces were tied. The results demonstrate that the highest von Mises stress was shown in the prepared tooth of the acrylic resin model, which is a temporary prosthesis, and the pulpal pressure was also the highest. Additionally, among the final prosthesis, the highest stress was shown in the hybrid ceramic model prepared teeth. The properties of restoration materials can be a factor influencing the tooth structure. Thus, in order to make a correct decision when selecting a material for restorative treatment, it is necessary to understand, analyze, and evaluate the properties of these restoration materials.

4.
Artigo em Inglês | MEDLINE | ID: mdl-36361346

RESUMO

Globally, the incidence of gastric cancer is lower in women than in men. It is thought that menstrual and reproductive factors may be related to their lower incidence of gastric cancer. This cross-sectional study examined menstrual, reproductive, and other factors in 20,784 postmenopausal women from the 2007-2020 Korea National Health and Nutrition Examination Survey (KNHANES). A univariate logistic regression analysis was performed, and then a multivariate logistic regression analysis for significant factors in the univariate analysis was conducted. In the multivariate logistic regression analysis, the age at menarche (odds ratio [OR] 1.08, 95% confidence interval [CI] 1.00-1.06, p = 0.035) and myocardial infarction (OR 2.43, 95% CI 1.05-5.62, p = 0.026) showed a significant association with increased incidence of gastric cancer. The age at menopause (OR 0.97, 95% CI 0.95-1.00, p = 0.03), the age at the first childbirth (OR 0.93, CI 0.89-0.97, p = 0.007), and the experience of alcohol consumption (OR 0.68, 95% CI 0.5-0.91, p = 0.003) showed a significant association with a decreased incidence of gastric cancer. Late menarche, early menopause, early aged first childbirth, and myocardial infarction are estimated to be risk factors for gastric cancer in postmenopausal Korean women.


Assuntos
Infarto do Miocárdio , Neoplasias Gástricas , Masculino , Feminino , Humanos , Idoso , Inquéritos Nutricionais , Estudos Transversais , Pós-Menopausa , Neoplasias Gástricas/epidemiologia , Neoplasias Gástricas/etiologia , República da Coreia/epidemiologia , Fatores de Risco
5.
J Craniomaxillofac Surg ; 49(8): 719-725, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33722457

RESUMO

The aim of this study was to investigate the effect and timing of recombinant human parathyroid hormone analog (PTH) administration for preventing medication-related osteonecrosis of the jaws (MRONJ) using a murine model. After standardized MRONJ induction using zoledronic acid and dexamethasone injections, 48 female Sprague-Dawley rats were divided into four groups according to the timing of PTH administration before or after dental extraction. Rats were euthanized 3 weeks after dental extraction, followed by clinical and histologic analyses. No clinical improvements were observed in the preoperative and postoperative PTH groups, compared to controls (p = 0.638 and 0.496, respectively). However, on histological analysis, the number of empty lacunae reduced significantly, and the number of blood vessels increased in the preoperative PTH group (p = 0.004 and 0.002, respectively). The postoperative PTH group did not show significant differences for empty lacunae and blood vessels compared to controls (p = 0.075 and 0.194, respectively). The reduction in the empty lacunae and the increase in the blood vessels in the preoperative PTH group were significant compared to other groups, suggesting more viable bone tissue in this group. In perspective, preoperative PTH use may represent a better prophylactic regimen for preventing the occurrence of MRONJ after traumatic dental or surgical procedures, especially in patients with a history of long-term bisphosphonate administration or at high risk of developing MRONJ. However, the findings should be proven in further studies on other animals followed by clinical trials.


Assuntos
Osteonecrose da Arcada Osseodentária Associada a Difosfonatos , Conservadores da Densidade Óssea , Animais , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/etiologia , Osteonecrose da Arcada Osseodentária Associada a Difosfonatos/prevenção & controle , Conservadores da Densidade Óssea/efeitos adversos , Difosfonatos/efeitos adversos , Modelos Animais de Doenças , Feminino , Humanos , Arcada Osseodentária , Camundongos , Hormônio Paratireóideo , Ratos , Ratos Sprague-Dawley
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...